Replacement of the connection cable
The replacement of electric cable must
be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the
current regulations.
To replace the connection cable use only
H05V2V2-F T90 or equivalent type.
Make sure that the cable section is
applicable to the voltage load and the
working temperature. The yellow/green
earth wire (B) must be approximately 2
cm longer than the live and neutral wire
(A).
1. Connect the green and yellow (earth) wire to the
terminal which is marked with the letter 'E', or the
earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured blue.
3. Connect the brown (live) wire to the terminal which
is marked with the letter 'L'. It must always be
connected to the network phase. There must be no
cut or stray strands of wire present. The cord clamp
must be correctly attached to the outer sheath.
Building In
min. 55 mm
min. 650 mm
550 mm
min. 600 mm
30 mm
470 mm
min. 600 mm
A) supplied seal
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
The panel installed below the hob must be easy to
remove and let an easy access in case a technical
assistance intervention is necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections
12